<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: SNMP Fujitsu System Health v2 Sensor

The SNMP Fujitsu System Health v2 sensor monitors the status of a Fujitsu PRIMERGY server via the integrated Remote Management Controller (iRMC) and Simple Network Management Protocol (SNMP). The sensor might also work on other Fujitsu devices that have an iRMC available like PRIMEQUEST servers, some storage systems of the ETERNUS product line, and CELSIUS workstations in racks.

SNMP Fujitsu System Health v2 Sensor

SNMP Fujitsu System Health v2 Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: SNMP Fujitsu Systeemstatus v2
  • French: Fujitsu état du système v2 (SNMP)
  • German: SNMP Fujitsu Systemzustand v2
  • Japanese: SNMP Fujitsu システム正常性 v2
  • Portuguese: Funcionamento do sistema Fujitsu (SNMP) v2
  • Russian: Работоспособность системы Fujitsu по SNMP, версия 2
  • Simplified Chinese: SNMP Fujitsu 系统健康状况版本 2
  • Spanish: Salud de sistema Fujitsu (SNMP) v2

Remarks

  • This sensor requires SNMP to be enabled in the iRMC via ServerView.
  • Use an iRMC interface as parent device for this sensor.
  • This sensor does not support SNMP v1.
  • As of iRMC S5, additional counters for physical disks and logical disks are supported.
  • This sensor supports IPv6.
  • This sensor has a low performance impact.
  • This sensor uses lookups to determine the status values of one or more channels.

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

Setting

Description

Sensor Name

Enter a name to identify the sensor. By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets.

i_round_blueIf the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?

Parent Tags

The tags that the sensor inherits from its parent device, parent group, and parent probe.

i_round_blueThis setting is for your information only. You cannot change it.

Tags

Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.

i_round_blueIt is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).

i_round_blueFor performance reasons, it can take some minutes until you can filter for new tags that you added.

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • snmpfujitsusystemhealthsensor
  • snmp
  • systemhealth
  • fujitsu
  • irmc

Priority

Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority (i_priority_1) to the highest priority (i_priority_5).

System Specific

System Specific

System Specific

Setting

Description

Measurement

The type of measurement that this sensor monitors.

Sensor Version

The version of the sensor definition that was used to create this sensor.

Identifier

The value that the sensor uses to find the component in the OID table.

i_round_blueThe identifier has the following format: RowIndex | Unique | Measurement. For example, 1.1|BATT 3.0V|Voltage.

OID Index

The OID table index that this sensor uses.

Debug Options

Debug Options

Debug Options

Setting

Description

Result Handling

Define what PRTG does with the sensor result:

  • Discard result: Do not store the sensor result.
  • Store result: Store the last sensor result in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file names are Result of Sensor [ID].Data.txt and Result of Sensor [ID].log. This setting is for debugging purposes. PRTG overwrites these files with each scanning interval.

i_podThis option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.

i_round_blueIn a cluster, PRTG stores the result in the PRTG data directory of the master node.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how different channels are shown for this sensor:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Scanning Interval

Scanning Interval

Scanning Interval

i_square_cyanFor more information, see section Root Group Settings, section Scanning Interval.

Schedules, Dependencies, and Maintenance Window

i_round_blueYou cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.

Schedules, Dependencies, and Maintenance Window

Schedules, Dependencies, and Maintenance Window

i_square_cyanFor more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.

Access Rights

Access Rights

Access Rights

i_square_cyanFor more information, see section Root Group Settings, section Access Rights.

Channel Unit Configuration

i_round_blueWhich channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.

Channel Unit Configuration

Channel Unit Configuration

i_square_cyanFor more information, see section Root Group Settings, section Channel Unit Configuration.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

CPU Status

The CPU status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status

Fan Status

The fan status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

Memory Module Status

The memory module status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

Overall Status

The overall status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

i_round_blueThis channel is the primary channel by default.

Power Supply Status

The power supply status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

Temperature Status

The temperature status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

Voltage Status

The voltage status

  • Up status: OK
  • Warning status: Warning
  • Down status: Error
  • Unknown status: Unknown

i_round_blueThe sensor can also show CPU speed and core count, fan speed, number of correctable and uncorrectable errors of the memory module, service processor battery status, condition of the power supply, power limit status, and power consumption.

More

i_square_blueKNOWLEDGE BASE

What security features does PRTG include?

My SNMP sensors don’t work. What can I do?